{"id":3042,"date":"2025-05-29T11:42:23","date_gmt":"2025-05-29T10:42:23","guid":{"rendered":"https:\/\/wordpress.tusnovics.pl\/?p=3042"},"modified":"2025-05-29T11:42:23","modified_gmt":"2025-05-29T10:42:23","slug":"analiza-paliw-i-biopaliw-wzorce-petrochemiczne-accustandard-2025","status":"publish","type":"post","link":"https:\/\/wordpress.tusnovics.pl\/aktualnosci\/analiza-paliw-i-biopaliw-wzorce-petrochemiczne-accustandard-2025\/","title":{"rendered":"Analiza paliw i biopaliw | Wzorce petrochemiczne | AccuStandard 2025"},"content":{"rendered":"<div class=\"wp-block-image\">\r\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"350\" class=\"wp-image-2267\" src=\"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2023\/02\/Tusnovics-Accu-Paliwa.jpg\" alt=\"\" srcset=\"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2023\/02\/Tusnovics-Accu-Paliwa.jpg 600w, https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2023\/02\/Tusnovics-Accu-Paliwa-300x175.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><\/div>\r\n\r\n\r\n<p>Tusnovics Instruments oferuje wzorce AccuStandard przeznaczone do analiz w zakresie temperatury zap\u0142onu, destylacji, temperatury m\u0119tnienia, temperatury krystalizacji, lepko\u015bci oraz zawarto\u015bci wody w produktach naftowych metod\u0105 miareczkowania Karla Fischera.<\/p>\r\n\r\n\r\n\r\n<p>Producent jest akredytowany na zgodno\u015b\u0107 z norm\u0105 ISO 17034, a znakomita wi\u0119kszo\u015b\u0107 wzorc\u00f3w petrochemicznych znajduje si\u0119 w zakresie akredytacji.<\/p>\r\n<h2 style=\"font-weight: 400;\"><strong>Destylacja (ASTM D86)<\/strong><\/h2>\r\n<p style=\"font-weight: 400;\">Nowe certyfikowane materia\u0142y odniesienia, <strong>D-86-LR (niski zakres)<\/strong> i <strong>D-86-HR (wysoki zakres)<\/strong>, zosta\u0142y opracowane zgodnie z najnowsz\u0105 wersj\u0105 normy ASTM D86, aby pom\u00f3c w niezawodnej weryfikacji czasu reakcji urz\u0105dzenia do pomiaru temperatury. Jest to szczeg\u00f3lnie wa\u017cne, poniewa\u017c czas reakcji elektronicznego urz\u0105dzenia pomiarowego jest inny ni\u017c w przypadku tradycyjnie stosowanych termometr\u00f3w rt\u0119ciowych.<\/p>\r\n<h2 style=\"font-weight: 400;\"><strong>Lepko\u015b\u0107 kinematyczna (ASTM D445)<\/strong><\/h2>\r\n<p style=\"font-weight: 400;\">Rozszerzamy ofert\u0119 certyfikowanych materia\u0142\u00f3w odniesienia zaprojektowane dla metody badawczej ASTM D445 o dwa nowe produkty: <strong>D-445-04<\/strong> i <strong>D-445-05<\/strong> o <strong>certyfikowanych warto\u015bciach lepko\u015bci w temperaturze 40\u1d52C i 100\u1d52C<\/strong>. Dok\u0142adny pomiar lepko\u015bci kinematycznej ma zasadnicze znaczenie dla okre\u015blenia jako\u015bci produkt\u00f3w naftowych oraz w\u0142a\u015bciwo\u015bci p\u0142yni\u0119cia paliw ciek\u0142ych i olej\u00f3w smarowych.<\/p>\r\n<p>&nbsp;<\/p>\r\n<p style=\"font-weight: 400;\"><a href=\"https:\/\/www.accustandard.com\/media\/assets\/catalogsbrochures\/PHYSICAL_PROP_2024_6_LK.pdf\" target=\"_blank\" rel=\"noopener\">Pobierz katalog <strong>Petroleum Physical Property Standards 2025 &gt;&gt;&gt;<\/strong><\/a><\/p>\r\n<p>&nbsp;<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\">Wzorce AccuStandard dla metod ASTM:<\/h3>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>destylacja | ASTM D86<\/li>\r\n\r\n\r\n\r\n<li>lepko\u015b\u0107 | ASTM D445<\/li>\r\n\r\n\r\n\r\n<li>temperatura zap\u0142onu | ASTM D56, D92 oraz D93<\/li>\r\n\r\n\r\n\r\n<li>temperatura krystalizacji | ASTM D1015, D2386, D5972s<\/li>\r\n\r\n\r\n\r\n<li>temperatura m\u0119tnienia | ASTM D2500, D5771, D5772 oraz D5773<\/li>\r\n\r\n\r\n\r\n<li>temperatura p\u0142yni\u0119cia | ASTM D97<\/li>\r\n\r\n\r\n\r\n<li>zawarto\u015b\u0107 wody | ASTM D1744, E1064, D4377, D4928 oraz D6304<\/li>\r\n\r\n\r\n\r\n<li>siarka w produktach naftowych | ASTM D2622, D3120, D3246, D4294, D5453, D6334, D6445<\/li>\r\n\r\n\r\n\r\n<li>siarka w biodieslu | ASTM D6751 i ASTM D5453<\/li>\r\n\r\n\r\n\r\n<li>pozosta\u0142e analizy fizykochemiczne<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p>&nbsp;<\/p>\r\n\r\n\r\n\r\n<p>&nbsp;<\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>Tusnovics Instruments oferuje wzorce AccuStandard przeznaczone do analiz w zakresie temperatury zap\u0142onu, destylacji, temperatury m\u0119tnienia, temperatury krystalizacji, lepko\u015bci oraz zawarto\u015bci wody w produktach naftowych metod\u0105 miareczkowania Karla Fischera.<\/p>\n","protected":false},"author":3,"featured_media":2268,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3042","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"acf":{"seo_content":{"intro":"","full":""},"main_banner":{"image":{"ID":1303,"id":1303,"title":"Tusnovics Instruments Aktualno\u015bci","filename":"Tusnovics-Instruments-Aktualnosci.jpg","filesize":169303,"url":"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2021\/03\/Tusnovics-Instruments-Aktualnosci.jpg","link":"https:\/\/wordpress.tusnovics.pl\/aktualnosci\/tusnovics-instruments-aktualnosci\/","alt":"","author":"1","description":"","caption":"","name":"tusnovics-instruments-aktualnosci","status":"inherit","uploaded_to":545,"date":"2021-03-01 22:37:20","modified":"2021-03-01 22:37:20","menu_order":0,"mime_type":"image\/jpeg","type":"image","subtype":"jpeg","icon":"https:\/\/wordpress.tusnovics.pl\/wp-includes\/images\/media\/default.png","width":1920,"height":500,"sizes":{"thumbnail":"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2021\/03\/Tusnovics-Instruments-Aktualnosci-150x150.jpg","thumbnail-width":150,"thumbnail-height":150,"medium":"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2021\/03\/Tusnovics-Instruments-Aktualnosci-300x78.jpg","medium-width":300,"medium-height":78,"medium_large":"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2021\/03\/Tusnovics-Instruments-Aktualnosci-768x200.jpg","medium_large-width":768,"medium_large-height":200,"large":"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2021\/03\/Tusnovics-Instruments-Aktualnosci-1024x267.jpg","large-width":1024,"large-height":267,"1536x1536":"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2021\/03\/Tusnovics-Instruments-Aktualnosci-1536x400.jpg","1536x1536-width":1536,"1536x1536-height":400,"2048x2048":"https:\/\/wordpress.tusnovics.pl\/wp-content\/uploads\/2021\/03\/Tusnovics-Instruments-Aktualnosci.jpg","2048x2048-width":1920,"2048x2048-height":500}},"title":"Analiza paliw i biopaliw | Wzorce petrochemiczne | AccuStandard 2025","subtitle":""},"seo":{"title":"Analiza paliw i biopaliw | Wzorce petrochemiczne | AccuStandard 2025","description":"","keywords":""}},"_links":{"self":[{"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/posts\/3042","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/comments?post=3042"}],"version-history":[{"count":2,"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/posts\/3042\/revisions"}],"predecessor-version":[{"id":3044,"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/posts\/3042\/revisions\/3044"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/media\/2268"}],"wp:attachment":[{"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/media?parent=3042"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/categories?post=3042"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wordpress.tusnovics.pl\/wp-json\/wp\/v2\/tags?post=3042"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}